Tenders/Delivery of a device for measuring pulse wave velocity by applanation tonometry using two measurement points for the needs of research group 3.1.17 in the implementation of project BG-RRP-2.004-0004-C01: "Strategic research and innovation program for the development of Medical University – Sofia", funded by the National Recovery and Resilience Plan
Awarded🇧🇬BulgariaSupplies

Delivery of a device for measuring pulse wave velocity by applanation tonometry using two measurement points for the needs of research group 3.1.17 in the implementation of project BG-RRP-2.004-0004-C01: "Strategic research and innovation program for the development of Medical University – Sofia", funded by the National Recovery and Resilience Plan

Auto-translated from bg
Original title: Доставка на апарат за измерване на скоростта на пулсовата вълна посредством апланационна тонометрия посредством две точки на измерване за потребностите на научноизследователска група 3.1.17 в изпълнение на проект BG-RRP-2.004-0004-C01: „Стратегическа научноизследователска и иновационна програма за развитие на Медицински университет – София“, финансиран от НПВУ
МЕДИЦИНСКИ УНИВЕРСИТЕТ
Published: Nov 9, 2026
Updated: Nov 12, 2026
Source: TED - Tenders Electronic Daily (EU)

This tender has been awarded

The contracting authority has selected an awardee for this tender.

Browse open Health & Medical tenders in Bulgaria

About This Opportunity

This is a supplies contract in the health and medical services sector. Located in Bulgaria, Europe, this opportunity is open to firms and consortiums, with an estimated budget of EUR 14,863.

Published through TED - Tenders Electronic Daily (EU), a national government procurement portal. Public procurement tenders follow the country's national bidding regulations and may have specific eligibility and documentation requirements for the supply of goods in the health and medical services sector. Supply contracts typically require bidders to demonstrate product compliance with technical specifications, delivery capacity, and relevant certifications. This contract has already been awarded. The information is published for transparency and market intelligence purposes.

Description

Auto-translated from bg
The subject of this public procurement is a device for measuring pulse wave velocity by applanation tonometry using two measurement points for the needs of research group 3.1.17 in the implementation of the project "Vascular aging. Molecular-biological, genetic and clinical-instrumental phenotyping – a prerequisite for early risk assessment of disease development and personalized treatment", as part of project BG-RRP-2.004-0004-C01: "Strategic research and innovation program for the development of Medical University – Sofia", funded by the National Recovery and Resilience Plan. The estimated value and minimum technical requirements are described in detail in the Technical Specification of the documentation. Device for measuring pulse wave velocity using two pulse wave recording points by the applanation tonometry method in the absence of the possibility of examination by cuff measurement. Measured and calculated parameters: a. The two tonometers must allow PWV measurement by simultaneous recording of pulse waves at two arterial points b. Option to measure pulse wave velocity in two stages, using the R wave of the ECG's QR complex as a reference c. Validated assessment of central hemodynamic parameters, directly based on the carotid (central) pressure wave recording, without using any "transfer" function d. Ability to capture pressure and electrocardiographic signals with high resolution (16 bits) and high sampling frequency (1000 Hz) e. Ability to measure pulse wave velocity, central aortic pressure, as well as apply analysis to separate the pulse wave into forward and reflected components f. Ability to perform continuous analysis of the indicated parameters within a 24-hour period g. Display of signal quality index in real-time h. Management of a patient database with the ability to export data i. Option and ability to measure and calculate the following parameters: ● Central systolic blood pressure (cSBP) ● Central pulse pressure (cPP) ● Mean arterial pressure (MAP) ● Augmentation phenomenon ● Form factor (FF) ● Augmentation index (AIx) ● Global reflection coefficient (GRC) ● Pulse wave separation analysis ● Early systolic pulse wave slope ● Pulse pressure variability ● Heart rate variability ● End-systolic blood pressure (ESBP) ● Mean systolic blood pressure (MSBP) ● Mean diastolic blood pressure (MDBP) ● Isovolumetric contraction time (ICT) ● Pre-ejection period (PEP) ● Left ventricular ejection time (LVET) ● Diastolic time (DT) ● Real subendocardial viability ratio (SEVR) 3. Wireless system for data operation, storage, and analysis 4. Technical parameters of the device: a. Acquisition: 16 bits b. Sampling frequency: 1000 S/sec c. Wireless connection: ISM @ 2.4 GHz d. Resolution: 0.004 mmHg e. Differential range: ≥ 220 mmHg f. Maximum shock: ≤ 150 g g. Maximum vibration: ≤ 20 g @ 10 Hz ⟶ 2 KHz sinusoidal h. ECG unit with ECG cable i. Resolution: 0.15 μV j. Range: ≥ ± 5 mV k. Maximum vibration: ≤ 20 g @ 10 Hz ⟶ 2 KHz sinusoidal l. USB wireless signal receiver m. Stand for mounting the tonometer unit and all other devices with height adjustment capability n. Real-time navigation with icons and step-by-step instructions for personnel to ensure correct procedure o. Generation of a configurable final report, which should include: i. Simplified patient report ii. Detailed physician report, with interpretations and trend graphs of various parameters p. Ability to connect to an external printer q. Ability to connect to a computer via cable or wirelessly and transfer data r. Mains and battery power, battery capacity up to 90 minutes of operation s. Synchronization: synchronization interface for subsequent ob...

Data provenance

This notice is sourced from TED - Tenders Electronic Daily (EU) and was originally published on November 9, 2026. Last refreshed 6 days ago. Original language: bg. BidsFactory mirrors official procurement notices and links back to the source for full legal text.

About МЕДИЦИНСКИ УНИВЕРСИТЕТ

МЕДИЦИНСКИ УНИВЕРСИТЕТ has issued 206 procurement notices on BidsFactory, including 6 currently open and 173 awarded contracts. Activity concentrates in Health & Medical, Research & Innovation, and Information & Communication Technology. All notices are published for Bulgaria. Notices are distributed via TED - Tenders Electronic Daily (EU). Most recent publication: November 16, 2026.

МЕДИЦИНСКИ УНИВЕРСИТЕТ: buyer profile, tenders and awards

Frequently asked questions about this tender

Where will the contract be performed?

The contract is for delivery in Bulgaria. Foreign bidders should review local registration, taxation, and any in-country presence requirements before submitting.

How can I submit a bid?

Visit TED - Tenders Electronic Daily (EU) to access the full notice, required documents, and submission instructions provided by the contracting authority.

Is this tender still open?

No — the contracting authority has selected an awardee for this notice. The record is kept for transparency and market intelligence.

Who is the contracting authority?

This notice was issued by МЕДИЦИНСКИ УНИВЕРСИТЕТ in Bulgaria. The authority is responsible for evaluating bids, awarding the contract, and managing performance.

What type of contract is this?

This is a Supplies contract in the Health & Medical sector. The classification helps bidders match the opportunity to their qualifications and registered scope of supply.

What is the estimated budget?

The estimated contract value is €14,863. Bidders should ensure their proposals are consistent with this range and account for any local taxes and contract execution costs.