About This Opportunity

This is a works contract in the construction and civil works sector, with a focus on Buildings. Located in Germany, Europe, this opportunity is open to firms and consortiums.

Published through TED - Tenders Electronic Daily (EU), a national government procurement portal. Public procurement tenders follow the country's national bidding regulations and may have specific eligibility and documentation requirements for civil works in the construction and civil works sector. Works contracts of this nature generally require demonstrated experience in similar infrastructure projects, adequate equipment and technical personnel, and financial capacity including bank guarantees. Interested parties should review the full documentation on the original source before submitting their proposal.

Description

Auto-translated from German
The medium-voltage switchgear must be manufactured with the following technical and design features: · The medium-voltage section must be designed so that the primary technical components can be operated maintenance-free or with low maintenance over the intended technical service life and are largely independent of external environmental influences. · Compact, space-saving design with the smallest possible switchgear panel dimensions due to gas-insulated design. · Arc-fault tested design in accordance with IEC 62271-200, classification at least IAC A FL or corresponding to the required installation type IAC A FLR. · No work on the insulating gas should be required on site for assembly, expansion, and operation. · The insulation system must be permanently gas-tight and hermetically sealed. · Use of an F-gas-free insulating medium without fluorinated greenhouse gases. · The insulating medium used should consist exclusively of components of the ambient air or comparable environmentally compatible gas mixtures. · Three-pole, compartment-wise hermetic encapsulation of the primary part made of corrosion-resistant metallic material, preferably stainless steel. · Hermetically sealed primary encapsulation of the live main current path. · All switching devices must be operable from the switchgear panel front. · Use of vacuum circuit breakers with the possibility of electrical remote control. · The insulating properties of the insulating medium used must be constantly and reliably guaranteed over the intended operating period. · Current transformers of the branch compartments should preferably be arranged as ring-core current transformers outside the hermetic primary encapsulation, so that they are not exposed to dielectric stress from the insulating medium. · Voltage transformers must be provided in touch-proof, pluggable design. · Actuators, auxiliary switches, and other mechanical operating devices of the switching devices must be located outside the high-voltage rooms and must be accessible for maintenance and testing purposes. · The system must be designed for high operational and supply reliability as well as high personal safety. · An appropriate pressure relief device for the event of an arc fault must be provided. · Capacitive voltage taps or a capacitive voltage testing system must be provided at the cable branches. This must enable safe detection of the absence of voltage at the switchgear panel front without impairing the intended degree of contact and protection of the switchgear. · The switchgear must be designed in such a way that later expansion of the system is possible with the least possible disruption to ongoing operations and without long-term shutdown of the entire system. · The entire medium-voltage switchgear must be designed in accordance with the currently valid technical connection conditions, guidelines, and specifications of the responsible local grid operator. · Requirements for sustainability and environmental compatibility For the medium-voltage switchgear, the following requirements must be taken into account in particular: · Use of an F-gas-free and environmentally compatible insulating medium. · The insulating medium should consist of natural components or components found in the ambient air. · Compact design for efficient use of existing switchgear spaces. · High supply reliability through low-maintenance or maintenance-free primary technology. · Ensuring high personal safety through appropriate encapsulation, grounding, interlocking, touch protection, and pressure relief. · Design of the system taking into account professional, resource-saving, and environmentally compatible dismantling and disposal at the end of its service life. · For the offered switchgear, an Environmental Product Declaration or comparable proof of the environmental impacts of the product based on a life cycle assessment must be submitted. · The life cycle ass...

Data provenance

This notice is sourced from TED - Tenders Electronic Daily (EU) and was originally published on November 10, 2026. Last refreshed 5 days ago. Original language: German. BidsFactory mirrors official procurement notices and links back to the source for full legal text.

About Kreis Recklinghausen, Der Landrat

Kreis Recklinghausen, Der Landrat has issued 124 procurement notices on BidsFactory, including 13 currently open and 44 awarded contracts. Activity concentrates in Construction & Civil Works, Information & Communication Technology, and Education & Training. All notices are published for Germany. Notices are distributed via TED - Tenders Electronic Daily (EU), service.bund.de (Germany), and Vergabe NRW (Germany). Most recent publication: November 18, 2026.

Kreis Recklinghausen, Der Landrat: buyer profile, tenders and awards

Frequently asked questions about this tender

Who is the contracting authority?

This notice was issued by Kreis Recklinghausen, Der Landrat in Germany. The authority is responsible for evaluating bids, awarding the contract, and managing performance.

What type of contract is this?

This is a Works contract in the Construction & Civil Works sector. The classification helps bidders match the opportunity to their qualifications and registered scope of supply.

Where will the contract be performed?

The contract is for delivery in Germany. Foreign bidders should review local registration, taxation, and any in-country presence requirements before submitting.

How can I submit a bid?

Visit TED - Tenders Electronic Daily (EU) to access the full notice, required documents, and submission instructions provided by the contracting authority.

Find tenders like this automatically

Premium shows the full details of every tender like this one and alerts you instantly when a new one is published.

See plans

Key Details

Contract Type
Works
Eligibility
Firms / Consortiums
Language
German

Source

ted
TED - Tenders Electronic Daily (EU)
Public Procurement

Contracting Authority

Kreis Recklinghausen, Der Landrat
🇩🇪Germany